CLINICAL_TRIALS
ClinicalTrials.gov record update
Evaluation of the Effectiveness of Irreversible Electroporation for the Treatment of Prostate Cancer
This page presents selected fields from the linked source record. It does not add a medical interpretation.
Record identity and dates
- Source
- ClinicalTrials.gov
- Source record ID
- NCT06886321
- Title field or adapter rule
- {'original_value': 'Evaluation of the Effectiveness of Irreversible Electroporation for the Treatment of Prostate Cancer', 'source_field': 'protocolSection.identificationModule.officialTitle'}
- Ingested At
- 2026-11-01T01:03:06.558654+00:00
- Published At
- 2026-10-27T00:00:00+00:00
- Record Updated At
- 2026-10-27
- Source Retrieved At
- 2026-11-01T01:03:05.968908+00:00
- Timestamp Basis
- ClinicalTrials.gov API/RSS response retrieval timestamp recorded by Dossier adapter
- Date limitation
- ClinicalTrials.gov API/RSS response retrieval timestamp recorded by Dossier adapter
Fields recorded by this source
- protocolSection.conditionsModule.conditions
["Prostate Cancer"]- protocolSection.statusModule.lastUpdatePostDateStruct
{"date": "2026-10-27", "type": "ACTUAL"}- protocolSection.identificationModule.nctId
"NCT06886321"- protocolSection.identificationModule.officialTitle
"Evaluation of the Effectiveness of Irreversible Electroporation for the Treatment of Prostate Cancer"- protocolSection.statusModule.overallStatus
"RECRUITING"- protocolSection.designModule.phases
["NA"]- protocolSection.statusModule.resultsFirstPostDateStruct
null
Study condition terms
Interventions recorded in this study
- {'armGroupLabels': ['Prostate Irreversible Electroporation'], 'description': 'The Prostate Irreversible Electroporation procedure was performed in our institution by a single urologist using an Prostate Irreversible Electroporation device and 18-gauge electrodes (Nanoknife®; Angiodynamics, Queensbury, NY, USA). All patients were positioned in lithotomy position under general anesthesia. A transrectal ultrasound was used to visualize the prostate and a brachytherapy grid was used to place the electrodes. An indwelling catheter was placed to empty the bladder. Four to six electrodes were placed through the perineum via the template grid to surround the targeted lesion. The lesion was defined based on prostate biopsy and MRI images. The active tip varied between 15- and 20-mm exposure. The distances between the electrodes were measured using TRUS and entered into the Nanoknife system. An initial ten pulses were delivered to ensure sufficient current was delivered between the electrodes (20-40 A). If sufficient then the remaining 80 pulses were given.', 'name': 'Prostate Irreversible Electroporation', 'type': 'DEVICE'} (protocolSection.armsInterventionsModule.interventions[])
An intervention appearing in a study record does not establish an effect or an approved use.
This index keeps the source fields it imported; it may not contain the complete original record. Verify wording and context in the linked source.